Si2400
Rev. 1.3 61
Reset settings = 0000_0000
b
(0x00)
S62 (RC). Result Codes Override
BitD7D6D5D4D3D2D1D0
Name
CLD OCR LLC WOR FLS IR NLR RR
Type R/W R/W R/W R/W R/W R/W R/W R/W
Bit Name Function
7CLDCarrier Loss Detector.
0 = Default.
1 = Caller ID sensitivity can be increased by 5 dB. When CLD = 1, the host is responsi-
ble for terminating caller ID reception by asserting an escape and issuing the ATH com-
mand.
Note: This bit also controls the carrier loss detection of non-caller ID modes of operation.
Therefore, the host must set CLD = 0 prior to answering a call via “ATA” or initiating a call
via “ATDT” or “ATDP”.
6OCROvercurrent Result Code (“x”).
0=Enable.
1=Disable.
5LLC
Low Loop Current (required for CTR21 operation).
This feature only works when SDF ≠ 0x00.
0 = Disable.
1 = Enable.
4WOR
Wake-On-Ring Alert.
0 = Alert is not asserted upon a wake-on-ring event.
1 = Alert is asserted upon a wake-on-ring event SE2[7:6] (GPIO4) = 11
b
.
3FLS
Hookswitch Flash Result Code (“f”).*
0 = Disable.
1 = Enable.
2IR
Intrusion Result Code (“I” and “i”).*
0 = Disable.
1 = Enable.
1NLR
No Phone Line Result Code (“L” and “l”).*
0 = Disable.
1 = Enable.
0RR
Ring Result Code (“R”).*
0 = Disable.
1 = Enable.
*Note: S62[3] (FLS), S62[2] (IR), S62[1] (NLR), and S62[0] (RR) only apply if S14[7] (MRCD) = 1.